loader image
Close
Skip to content

WhatsApp Facebook Instagram YouTube Email
Proficiency Testing
  • Home
  • PT Calendar
  • About us
  • Certificate
  • Contact Us
  • Envirocare Labs
  • 9th PTP Conclave Gallery

Facebook Twitter Instagram
Proficiency Testing

2026MWW01R2 Instruction sheet and Result Submission

PT Round 2026MWW01R2

Step 1 of 5

20%

Instructions to Participants

Please read carefully before starting analysis

Quick Safety & Handling

  • Only trained and authorized personnel should handle PT items.
  • Confirm sample integrity upon receipt; notify the PT Provider if damaged.
  • Record date of receipt and store under the specified conditions until analysis.
  • Initiate analysis within 48 hours of receipt.
  • Treat PT items like routine samples and use standard methods unless otherwise instructed.

Program Details

Program Code: 2026MWW01R2 Category: Waste Water Measurand: Total coliform, Escherichia coli, & Faecal coliform Result Submission: 04 July 2026 Storage: 2–8 °C until analysis

Revival Instructions

Vial 2026MWW01R2

  1. Uncap the sample vial 2026MWW01R2 aseptically and rehydrate using 5ml sterile saline peptone water (0.1% peptone with 0.85% NaCl).
  2. Securely recap and allow 5 minutes rehydration at room temperature.
  3. Tranfer entire rehydrate vial content to 100 ml of sterile distilled water, ensuring thorough homogenization of the sample.
  4. Treat this as your sample and carry out the analysis for the Total coliform, Escherichia coli & Faecal coliform.

Raw Data Submission

  • Upload clear photographs of plates for all analytes tested.
  • Upload photographs of biochemical tests performed.
  • Accepted formats: JPG, PNG, PDF  |  Max size: 5 MB each.
Note: Ensure images are in focus and labeled with sample ID, dilution, and date.

Reporting of Results

PT Round: 2026MWW01R2

Analytes to Report

For this PT round 2026MWW01R2, you are required to report results for the following analytes:

Total Coliform
Reporting Basis: MPN/100ml
APHA 9221 24th Edition, IS 1622
Escherichia coli
Reporting Basis: MPN/100ml
APHA 9221 24th Edition, IS 1622
Faecal coliform
Reporting Basis: MPN/100ml
APHA 9221 24th Edition, IS 1622
Online submission only: Do not download/print this page. Use the Next button to proceed to result entry.

Key Instructions (Read before you begin)

  • Do NOT download or print this page — results must be entered and submitted online only.
  • Use the Next button at the bottom to go to the results entry section.
  • Double-check all entries before submission — changes may not be accepted after submission.
  • Retain all raw data and supporting records (e.g., plate photographs, biochemical results, calibration logs) as per ISO/IEC 17025.
  • Upload clear evidence where required — unclear/missing records may lead to disqualification.
  • Avoid collusion — responsibility lies entirely with the participant.
  • Click Submit once only — unsolicited re-submissions may result in only the first entry being considered.
  • If you cannot proceed, ensure all required fields are completed.
  • You will see a confirmation message upon successful submission.
  • Use the specified methods, or an equivalent validated method capable of required accuracy. Obtain prior written permission for deviations.
  • Results in inappropriate formats (e.g., “<”, “>”, or zero where not applicable) may not be considered.
  • Read and follow the PT Protocol carefully before starting analysis.
Consent(Required)
Please click on the consent to proceed with the result submission.

PT Result Submission

Program Code: 2026MWW01R2

Last Date for Result Submission: 4th July 2026


Note: All fields are mandatory.

Before starting the analysis, please ensure you have read the handling and analysis instructions carefully.

Please enter a number from 1 to 30.
For lab code, refer to the sample forwarding letter sent along with the sample
DD dot MM dot YYYY
As filled in the registration form
DD dot MM dot YYYY
DD dot MM dot YYYY

Section 1

Please select the appropriate vial code
Please select the appropriate measurand
Please enter a number from 2 to 1600.
Do not enter values in decimal points or symbols “greater than” or “less than”, etc. Values reported less that 2 or 1.8 wont be considered for final evaluation as per the standards, these values will be marked as RNC in the final report.
Please report results in set format E.g.: “5-4-1”
e.g. 37 Degrees for 24 hrs
Any Confirmatory/Biochemical Tests Performed and their results. Please put NA if not applicable.

Section 2

Please select the appropriate vial code
Please select the appropriate measurand
Please enter a number from 2 to 1600.
Do not enter values in decimal points or symbols “greater than” or “less than”, etc. Values reported less that 2 or 1.8 wont be considered for final evaluation as per the standards, these values will be marked as RNC in the final report.
Please report results in set format E.g.: “5-4-1”
e.g. 37 Degrees for 24 hrs
Any Confirmatory/Biochemical Tests Performed and their results

Section 3

Please select the appropriate vial code
Please select the appropriate measurand
Please enter a number from 2 to 1600.
Do not enter values in decimal points or symbols “greater than” or “less than”, etc. Values reported less that 2 or 1.8 wont be considered for final evaluation as per the standards, these values will be marked as RNC in the final report.
Please report results in set format E.g.: “5-4-1”
e.g. 37 Degrees for 24 hrs
Any Confirmatory/Biochemical Tests Performed and their results
Max. file size: 512 MB.
Upload clear photographs of plates, positive tubes and biochemical tests performed for all measurand or parameter tested. Please all data needs to be uploaded in a single file only.
(Choose Yes/No as per the applicability)

Organizations’ Details

e.g. TC xxxxx
Consent(Required)
I hereby confirm that I am authorized to submit this form. I have thoroughly checked and updated all required fields to ensure accuracy. I fully understand that once this form is submitted, the results cannot be altered under any circumstances. Furthermore, I acknowledge and accept full responsibility for the accuracy and completeness of all information provided in this submission.

Registered Office

Envirocare Labs Private Limited Enviro House, A7-A8, MIDC Road, Wagle Estate, Thane, Maharashtra, India 400604
Corporate Identity Number: U99999MH1988PTC045938
Working Hours: 
9:00 am to 5:30 pm (Monday to Saturday) 
For any queries or grievances, contact us at pt@envirocare.co.in

Quick link

  • Login/Create Account
  • Privacy Policy
  • Refund Policy
  • Cookie Policy
  • Terms & Conditions
  • PT Protocol
  • Code of Conduct
  • Envirocare Labs

Partners

  • Green Alliance

All Rights Reserved I Envirocare Labs PT Cell I 2023

  • Home
  • PT Calendar
  • About us
  • Certificate
  • Contact Us
  • Envirocare Labs
  • 9th PTP Conclave Gallery