loader image
Close
Skip to content

WhatsApp Facebook Instagram YouTube Email
Proficiency Testing
  • Home
  • PT Calendar
  • About us
  • Certificate
  • Contact Us
  • Envirocare Labs
  • 9th PTP Conclave Gallery

Facebook Twitter Instagram
Proficiency Testing

2025MW05R1 Instruction sheet and Result submission

PT Round 2025MW05R1

Step 1 of 6

16%

Instructions to Participants

Please read carefully before starting analysis

Quick Safety & Handling

  • Only trained and authorized personnel should handle PT items.
  • Confirm sample integrity upon receipt; notify the PT Provider if damaged.
  • Record date of receipt and store under the specified conditions until analysis.
  • Initiate analysis within 48 hours of receipt.
  • Treat PT items like routine samples and use standard methods unless otherwise instructed.

Program Details

Program Code: 2025MW05R1 Category: Water Matrix: Suspension Measurand: MS2 Phage Result Submission: 05 Jan 2026 Storage: 2–8 °C until analysis

Revival Instructions

2025MW05R1-1

  1. Do not divide the content of the suspension; test it all at once.
  2. Aseptically remove the cap of container.
  3. Mix entire contents of the suspension from labeled 2025MW05R1-1 to 100 ml of distilled water and leave it at room temperature for five minutes.
  4. Perform serial dilutions of the sample up to 1:100000 & proceed as per standard procedure.
  5. Count the number of plagues per 100ml of sample.
  6. Repeat this procedure for 2025MW05R1-2.

Raw Data Submission

  • Upload clear photographs of plates for all analytes tested.
  • Upload photographs of biochemical tests performed.
  • Accepted formats: JPG, PNG, PDF.
Note: Ensure images are in focus and labeled with sample ID, dilution, and date.

Reporting of Results

PT Round: 2025MW05R1

Analytes to Report

For this PT round 2025MW05R1, you are required to report results for the following analytes:

MS2 Phage
Reporting Basis: per 100ml
USEPA 1602
Online submission only: Do not download/print this page. Use the Next button to proceed to result entry.

Key Instructions (Read before you begin)

  • Do NOT download or print this page — results must be entered and submitted online only.
  • Use the Next button at the bottom to go to the results entry section.
  • Double-check all entries before submission — changes may not be accepted after submission.
  • Retain all raw data and supporting records (e.g., plate photographs, biochemical results, calibration logs) as per ISO/IEC 17025.
  • Upload clear evidence where required — unclear/missing records may lead to disqualification.
  • Avoid collusion — responsibility lies entirely with the participant.
  • Click Submit once only — unsolicited re-submissions may result in only the first entry being considered.
  • If you cannot proceed, ensure all required fields are completed.
  • You will see a confirmation message upon successful submission.
  • Use the specified methods, or an equivalent validated method capable of required accuracy. Obtain prior written permission for deviations.
  • Results in inappropriate formats (e.g., “<”, “>”, or zero where not applicable) may not be considered.
  • Read and follow the PT Protocol carefully before starting analysis.
Consent(Required)
Please click on the consent to proceed with the result submission.

PT Result Submission

Program Code: 2025MW05R1

Last Date for Result Submission: 05th January 2025


Note: All fields are mandatory.

Before starting the analysis, please ensure you have read the handling and analysis instructions carefully.

Please enter a number from 0 to 20.
For lab code, refer to the sample forwarding letter sent along with the sample
DD dot MM dot YYYY
As filled in the registration form
DD dot MM dot YYYY
DD dot MM dot YYYY

Section 1

Please select the appropriate vial code
Please select the appropriate measurand
Select appropriate option
e.g. 37 Degrees for 24 hrs
Any Confirmatory/Biochemical Tests Performed and their results

Section 2

Please select the appropriate vial code
Please select the appropriate measurand
Select appropriate option
e.g. 37 Degrees for 24 hrs
Any Confirmatory/Biochemical Tests Performed and their results
e.g. 37 Degrees for 24 hrs
Max. file size: 512 MB.
Upload clear photographs of plates, positive tubes and biochemical tests performed for all measurand or parameter tested.
(Choose Yes/No as per the applicability)

Organizations’ Details

e.g. TC xxxxx
Consent(Required)
I hereby confirm that I am authorized to submit this form. I have thoroughly checked and updated all required fields to ensure accuracy. I fully understand that once this form is submitted, the results cannot be altered under any circumstances. Furthermore, I acknowledge and accept full responsibility for the accuracy and completeness of all information provided in this submission.

Registered Office

Envirocare Labs Private Limited Enviro House, A7-A8, MIDC Road, Wagle Estate, Thane, Maharashtra, India 400604
Corporate Identity Number: U99999MH1988PTC045938
Working Hours: 
9:00 am to 5:30 pm (Monday to Saturday) 
For any queries or grievances, contact us at pt@envirocare.co.in

Quick link

  • Login/Create Account
  • Privacy Policy
  • Refund Policy
  • Cookie Policy
  • Terms & Conditions